Thermal inspection services

Aerial thermal inspections for commercial roofs, solar arrays and distribution infrastructure: one flight, clear data to plan your next steps.

Thermographic surveys

Heat, turned into insight

Radiometric thermal capture detects hotspots and abnormal heat patterns across roofs, solar arrays and electrical assets. Every finding is geolocated, paired with a visual image and prioritized for follow-up investigation.

Key detection capabilities

  • Abnormal heating at connectors and splices
  • Phase patterns consistent with load imbalance
  • Thermal anomalies in modules and strings
  • Moisture and insulation signatures in roofs
  • Early signs of component degradation
  • Repeatable baselines for trend analysis
Request a quote

Solar array — aerial thermography

Solar array, visual (RGB) capture
Visual (RGB)
Solar array, thermal capture
Thermal

Illustrative example

01 · Electrical assets

Distribution line inspection

Connections under load heat up when they loosen or corrode. Comparing similar components side by side shows which one is running hotter, with no climbing and no shutdown.

Distribution pole, visual (RGB) capture
Visual (RGB)
Distribution pole, thermal capture
Thermal

What we look for

Hot connectors, splices and clamps
Phase-to-phase patterns consistent with load imbalance
Abnormal heating at transformers and cutouts
Arresters, reclosers and other pole-mounted equipment
Damaged insulators, hardware and vegetation contact
GPS-located findings, pole by pole, with thermal + RGB pairs
  • Pole-by-pole locations
  • Thermal + RGB pairs
  • Phase comparisons
March–November · lines under load Request a quote →
02 · Roofing

Commercial roof inspection

High-resolution surveys for commercial and industrial sites, supporting maintenance and insurance.

Commercial roof, visual (RGB) capture
Visual (RGB)
Commercial roof, thermal capture
Thermal

What we look for

Warm zones in the roof fieldMay indicate trapped moisture or wet insulation.
Heat around vents and drainsMay point to seal or flashing deterioration.
Patterns at edges and parapetsMay be consistent with perimeter flashing issues.
Uneven heat lossMay suggest missing or damaged insulation.
  • Report in 48 h
  • Thermal + RGB pairs
  • GPS-tagged findings
  • Estimated area (m²)
Year-round · best on clear, calm nights Request a quote →
03 · Solar

Solar array inspection

A healthy panel heats evenly. Hot cells, strips or whole panels stand out in thermal and help your O&M team decide where to look first.

Solar array, visual (RGB) capture
Visual (RGB)
Solar array, thermal capture
Thermal

What we look for

Cell-level hotspots
Patterns consistent with bypass diode activation
Panels or strings not producing
Hot connectors and junction boxes
Soiling, debris and shading
Cracked glass and storm damage
  • Panel-level locations
  • Thermal + RGB pairs
  • Severity ranking

Roof areas beneath panels can't be assessed thermally.

April–October · sunny days, panels producing Request a quote →
Deliverables

Technical reports your teams can act on

Clear, structured reports that turn aerial data into maintenance priorities. Every finding is GPS-tagged, and roofing reports are delivered in 48 hours.

  • Findings catalog with severity ratings
  • Annotated imagery (RGB + thermal)
  • PDF report with GPS coordinates for every finding
  • Summary with recommended follow-up
UT-0417Roof Zone 4 — warm area, ΔT +4.4 °CHIGH
UT-0418Connector J-22 — abnormal heating, ΔT +41 °CHIGH
UT-0421String 14B — pattern consistent with bypass diode activationMODERATE
UT-0427Module A-19 — soiling patternLOW