Thermal imaging is one of the most useful screening tools for low-slope commercial roofs. Building envelope consultants also know that thermal data alone can be misread. The most reliable approach has two steps: a thermal scan to find where to look, and core samples to confirm what's there.
Step 1: The thermal scan
- Full coverage: a scan covers the whole accessible roof area, not just a sampling grid.
- Non-destructive: suspected wet areas are outlined without cutting the membrane.
- Targeted sampling: cores go where anomalies are, not at random.
Thermal anomalies don't always mean moisture. Common look-alikes include:
- Ducts or piping below the deck
- Changes in insulation thickness
- Concrete structure next to lighter steel deck
- Ballast, debris or surface material changes that affect emissivity
Step 2: Core sampling
A core cut through the roof assembly confirms what the scan suggests:
- Moisture presence: whether a thermal anomaly is wet insulation or something else.
- Roof assembly: cover board, insulation type, vapour retarder and layers.
- Deck condition: corrosion on steel, spalling on concrete or rot on wood beneath wet areas.
- Moisture content: lab testing by weight, when needed for warranty or legal disputes.
A combined workflow
Coring without a scan is guesswork: more cuts, missed wet areas and an incomplete picture. A report based only on unverified thermal images risks recommendations that lead to unnecessary tear-offs or failed repairs.
A common approach:
- Scan the roof under suitable conditions: after sunset, low wind, clear sky and a dry surface.
- Locate each thermal anomaly on a roof plan.
- Take cores in representative anomaly areas, plus at least one in a dry-reading reference area.
- Repair every core site with compatible materials.
- Compare the thermal map with the core results in the final assessment.
Utilisight provides steps 1 and 2 as an independent third party. Cores and repairs are carried out by your consultant or roofer.